{"id":493,"date":"2019-10-21T12:31:13","date_gmt":"2019-10-21T12:31:13","guid":{"rendered":"https:\/\/elettrostar.net?page_id=493"},"modified":"2021-02-11T12:04:25","modified_gmt":"2021-02-11T12:04:25","slug":"svi-ii-esd-emergency-shutdown-device","status":"publish","type":"page","link":"https:\/\/elettrostar.net\/en\/service-and-distribution-of-valves-of-the-masoneilan-and-consolidated-brands\/masoneilan-process-control-valves\/emergency-shut-down\/svi-ii-esd-emergency-shutdown-device\/","title":{"rendered":"SVI II ESD Emergency Shutdown Device"},"content":{"rendered":"\n<p>The SVI II ESD is a SIL3 capable partial stroke test controller and emergency shutdown device. <\/p>\n\n\n\n<p>Its safety and PST function are independent of each other, allowing the device to respond to a safety function while a test is active. <br>It can capture two shutdown events and allow continuous HART communications during a trip facilitating local panel annunciation using the built in discrete outputs. <\/p>\n\n\n\n<p>The SVI II ESD automatically captures and stores the PST results in its non-volatile memory while Valvue ESD software regularly interfaces and updates its database with PST and full stroke data.<\/p>\n\n\n\n<p><strong>Communication \/ Control Platform:<\/strong><br>\u2022 24Vdc or 4-20mA Safety function trip signal (SIL3)<br>\u2022 HART\u00ae and Switch(Discrete Output) fault annunciation<\/p>\n\n\n\n<p><strong>Pneumatics:<\/strong><br>\u2022 20 \u2013 120 psi Supply pressure<br>\u2022 Single-acting<\/p>\n\n\n\n<p><strong>Operating Temperature:<\/strong><br>\u2022 -40\u00baC to +85\u00baC<\/p>\n\n\n\n<p><strong>Materials:<\/strong><br>\u2022 Aluminum (painted) or Stainless Steel Housing<br>\u2022 Composite Polymers and Stainless Steel Pneumatics I\/O:<br>\u2022 4-20mA output and discrete Input<\/p>\n\n\n\n<p><strong>Mounting \/ Feedback:<\/strong><br>\u2022 Non-Contact magnetic position feedback<br>\u2022 Rotary or Linear<br>\u2022 Stainless Steel brackets for all Masoneilan and major valve brands<\/p>\n\n\n\n<p><strong>Certifications:<\/strong><br>\u2022 Explosion \/ Flame \/ Dust-proof and Intrinsically safe<br>\u2022 FM, CSA, ATEX, IECEx<br>\u2022 Regional \u2013 NEPSI, Taiwan TS, CCOE, CU-TR, AZS, UZ, INMETRO, JIS, KOSHA, IA<\/p>\n\n\n\n<p><strong>Diagnostics:<\/strong><br>\u2022 Partial Stroke Testing (PST)<\/p>\n\n\n\n<p><strong>Configuration \/ Monitoring Interfaces:<\/strong><br>\u2022 Local Display with Pushbuttons<br>\u2022 ValVue* ESD Device Diagnostic and Configuration Tool<br>\u2022 DTM or eDDL \u2013 seamless integration into leading asset management systems<\/p>\n","protected":false},"excerpt":{"rendered":"The SVI II ESD is a SIL3 capable partial stroke test controller and emergency shutdown device. Its safety and PST function are independent of each other, allowing the device to respond to a safety function while a test is active. It can capture two shutdown events and allow continuous HART communications during a trip facilitating&#8230; <a class=\"view-article\" href=\"https:\/\/elettrostar.net\/en\/service-and-distribution-of-valves-of-the-masoneilan-and-consolidated-brands\/masoneilan-process-control-valves\/emergency-shut-down\/svi-ii-esd-emergency-shutdown-device\/\">Read More<\/a>","protected":false},"author":1,"featured_media":491,"parent":67,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"template-product.php","meta":{"_acf_changed":false,"footnotes":""},"application":[15,14,9,13],"class_list":["post-493","page","type-page","status-publish","has-post-thumbnail","hentry","application-valves-used-in-the-chemical-sector","application-valves-for-use-in-oil-and-gas-sector","application-valves-for-use-in-power-plants","application-valves-for-refineries"],"acf":[],"_links":{"self":[{"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages\/493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/comments?post=493"}],"version-history":[{"count":3,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages\/493\/revisions"}],"predecessor-version":[{"id":1476,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages\/493\/revisions\/1476"}],"up":[{"embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages\/67"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/media\/491"}],"wp:attachment":[{"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/media?parent=493"}],"wp:term":[{"taxonomy":"application","embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/application?post=493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}