{"id":543,"date":"2019-10-21T14:16:22","date_gmt":"2019-10-21T14:16:22","guid":{"rendered":"https:\/\/elettrostar.net?page_id=543"},"modified":"2021-01-21T13:37:11","modified_gmt":"2021-01-21T13:37:11","slug":"525-526-series-pressure-reducing-back-pressure-differential-pressure-regulators","status":"publish","type":"page","link":"https:\/\/elettrostar.net\/en\/service-and-distribution-of-valves-of-the-masoneilan-and-consolidated-brands\/masoneilan-process-control-valves\/regulators\/525-526-series-pressure-reducing-back-pressure-differential-pressure-regulators\/","title":{"rendered":"525-526 Series Pressure Reducing, Back Pressure &#038; Differential Pressure Regulators"},"content":{"rendered":"\n<p><strong>Top and Bottom Guiding<\/strong><\/p>\n\n\n\n<p>A well accepted industry standard particularly suited for double seated plugs to provide adequate support against side loads.<\/p>\n\n\n\n<p><strong>High Capacity with Low Recovery<\/strong><\/p>\n\n\n\n<p>Flow capacity is at top levels for contemporary double seated regulators and is attained with very little pressure recovery as indicated by a high critical flow factor.<\/p>\n\n\n\n<p><strong>Reduced Capacity Trim<\/strong><\/p>\n\n\n\n<p>0.4 Factor Trim &#8211; the most practical double seated trim design giving a substantial reduction in capacity while maintaining desirable flow characteristics.<\/p>\n\n\n\n<p><strong>High Performance Materials<\/strong><\/p>\n\n\n\n<p>Materials of construction have been selected for high performance and long life when handling the high pressure drop capabilities of the valve.<\/p>\n\n\n\n<p><strong>High Temperature Applications<\/strong><\/p>\n\n\n\n<p>For temperatures over the rating of the diaphragm material, the regulator must be mounted with the actuator below the centerline of the regulator body. The diaphragm will be protected from the high temperature by a condensate barrier in the sensing line and actuator diaphragm case. If installed otherwise, an adequate condensate barrier must be incorporated. Consult factory for more information.<\/p>\n\n\n\n<p><strong>Configurations<\/strong><\/p>\n\n\n\n<p>Models 525 and 526 Regulators are designed for use with the 10900 Series Actuators for reducing, back pressure and differential pressure applications. Refer to Technical Specifications bulletin GEA19537A for actuator\u00a0selection.<\/p>\n\n\n\n<p><strong>Sizes:<\/strong> \u00be\u201d through 4\u201d<br>(20 through 100 mm)<\/p>\n\n\n\n<p><strong>Ratings and Connections:<\/strong><br>\u2022 Flanged: ANSI 150 &#8211; 600<br>UNI-DIN 10 -100<br>\u2022 Screwed: NPT<br>\u2022 Welded: BW or SW<\/p>\n\n\n\n<p><strong>Body Materials:<\/strong><br>\u2022 Carbon steel<br>\u2022 Stainless steel<br>\u2022 Chrome-moly<\/p>\n\n\n\n<p><strong>Actuator:<\/strong><br>\u2022 Model 10900 with springopposed<br>diaphragm<\/p>\n\n\n\n<p><strong>Trim:<\/strong><br>\u2022 Disc plug, double seat<\/p>\n\n\n\n<p><strong>Working Range:<\/strong><br>\u2022 0.5 to 330 psi<br>(0.034 to 22.7 bar)<\/p>\n","protected":false},"excerpt":{"rendered":"Top and Bottom Guiding A well accepted industry standard particularly suited for double seated plugs to provide adequate support against side loads. High Capacity with Low Recovery Flow capacity is at top levels for contemporary double seated regulators and is attained with very little pressure recovery as indicated by a high critical flow factor. Reduced&#8230; <a class=\"view-article\" href=\"https:\/\/elettrostar.net\/en\/service-and-distribution-of-valves-of-the-masoneilan-and-consolidated-brands\/masoneilan-process-control-valves\/regulators\/525-526-series-pressure-reducing-back-pressure-differential-pressure-regulators\/\">Read More<\/a>","protected":false},"author":1,"featured_media":544,"parent":75,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"template-product.php","meta":{"_acf_changed":false,"footnotes":""},"application":[],"class_list":["post-543","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages\/543","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/comments?post=543"}],"version-history":[{"count":2,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages\/543\/revisions"}],"predecessor-version":[{"id":1249,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages\/543\/revisions\/1249"}],"up":[{"embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/pages\/75"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/media\/544"}],"wp:attachment":[{"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/media?parent=543"}],"wp:term":[{"taxonomy":"application","embeddable":true,"href":"https:\/\/elettrostar.net\/en\/wp-json\/wp\/v2\/application?post=543"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}